References icon

References


страницы:   1   2   3



REFERENCES


  1. June-Ho Lee, Sung-Min Cho, Il-Keun Song, “Correlation between the AC breakdown strength and space charge distribution of water tree aged XLPE”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 657 – 660, Vol. 2, (1998).

  2. Varlow, B.R., Auckland, D.W., “Mechanical aspects of water treeing”, IEE Colloquium on Mechanical Influence on Electrical Insulation Performance, pp. 8/1-8/6, (28 Feb 1995).

  3. Hirai, N., Ohki, Y., Takeda, T., Okamoto, T., “Interpretation of the relation between residual charge and water trees in XLPE cables”, IEEE/PES, Transmission and Distribution Conference and Exhibition, Asia Pacific, Vol. 2, pp. 1094-1099, (6-10 Oct. 2002).

  4. Ross, R., “Water treeing theories: Current status, views and aims”, Proceedings of International Symposium on Electrical Insulating Materials, pp. 535 – 540, (27-30 Sept. 1998).

  5. Oyegoke, B., Hyvonen, P., Aro, M., Ning Gao, “Application of dielectric response measurement on power cable systems”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 10, No. 5, pp. 862 – 873, (Oct. 2003).

  6. Ahmed, M., Al-Ohali, M.A., Garwan, M.A., Al-Soufi, K., Narasimhan, S., “Analysis of water trees in underground HV cables using the KFUPM micro-PIXE facility”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 6, No. 1, pp. 95 – 99, (Feb. 1999).

  7. Patsch, R., Jung, J., “Water trees in cables: generation and detection”, IEE Proceedings- Science, Measurement and Technology, Vol. 146, No. 5, pp. 253 – 259, (Sept. 1999).

  8. Kon, H., Watanabe, K., Miyajima, K., Uchida, K., “New residual-charge measurement for water-tree deteriorated power cable”, Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials, Vol. 1, pp. 77–82, (1-5 June 2003).

  9. Shirai, Y., Kumazawa, T., Shimizu, N., “Water treeing in polyethylene at low temperature region (-196 C -10 C)”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 959 – 962, (20-24 Oct. 2002).

  10. Carmo Lanca, M., Dissado, L.A., “An estimate of the fractal dimension of water trees”, Seventh International Conference on Dielectric Materials, Measurements and Applications, (Conf. Publ. No. 430), pp. 214 – 219, (23-26 Sept. 1996).

  11. Radu, I., Acedo, M., Filippini, J.C., Notingher, P., Ftutos, F., “The effect of water treeing on the electric field distribution of XLPE and consequences for the dielectric strength”, IEEE Transactions on Dielectrics and Electrical Insulation,  Vol. 7, No. 6, pp. 860 – 868, (Dec. 2000).

  12. Bulinski, A.T., Crine, J.-P., Noirhomme, B., Densley, R.J., Bamji, S., “Polymer oxidation and water treeing”, IEEE Transactions on Dielectrics and Electrical Insulation,  Vol. 5, No. 4, pp. 558 – 570, (Aug. 1998).

  13. Dang, Z.M., Tu, D.-M., Nan, C.-W., “Effect of ethylene-acrylic acid and sorbital on the formation of water treeing in polyethylene”, Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials, Vol. 1,  pp. 364 – 367, (1-5 June 2003).

  14. Ross, R., Megens, M., “Dielectric properties of water trees”, Proceedings of the 6th International Conference on Properties and Applications of Dielectric Materials, Vol. 1,  pp. 455 – 458, (21-26 June 2000).

  15. Bulinski, A.T., So, E., Bamji, S.S., “Measurement of the harmonic distortion of the insulation loss current as a diagnostic tool for high voltage cable insulation”, IEEE Power Engineering Society Winter Meeting, Vol. 3, pp. 1615 – 1620, (23-27 Jan. 2000).

  16. Castellani, L., Peruzzotti, F., Zaopo, A., Cinquemani, P.L., Foulger, S., Filippini, J.C., Lachevre, V., “Water treeing retardant materials for cable insulators”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 1,  pp. 312 – 316, (19-22 Oct. 1997).

  17. Nagao, M., Akama, W., Yamamoto, T., Kosaki, M., “AC dissipation current waveform and space charge formation of water-tree-degraded polyethylene film”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 1, pp. 153 – 156,  (20-23 Oct. 1996).

  18. Ciuprina, F., Teissedre, G., Filippini, J.C., Notingher, P.V., “Crosslinking influence on water tree resistance in polyethylene”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 245 – 248, (14-17 Oct. 2001).

  19. Visata, O.I., Teissedre, G., Filippini, J.C., Notingher, P.V., “An investigation on the distribution of ions and water in water trees by FTIR microspectroscopy”, 7th International Conference on Solid Dielectrics (ICSD '01), pp. 373 – 376, (25-29 June 2001).

  20. El-Zein, A., “Analysis of water treeing in solid insulated cables”, IEEE International Symposium on Electrical Insulation, Vol. 1, pp. 113 – 116, (7-10 June 1998).

  21. Kaneko, D., Maeda, T., Ito, T., Ohki, Y., Konishi, T., Nakamichi, Y., Okashita, M., “Role of number of consecutive voltage zero-crossings in propagation of water trees in polyethylene”, IEEE Transactions on Dielectrics and Electrical Insulation,  Vol. 11, No. 4, pp. 708 – 714, (Aug. 2004).

  22. Suzuki, K., Tanaka, Y., Takada, T., Ohki, Y., Takeya, C., “Correlation between space charge distribution and water-tree location in aged XLPE cable”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 8, No. 1, pp. 78 – 81, (Feb 2001).

  23. Katsuta, G., Toya, A., Ying Li, Okashita, M., Aida, F., Ebinuma, Y., Ohki, Y., “Experimental investigation on the cause of harmfulness of the blue water tree to XLPE cable insulation”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 6, No. 6, pp. 887 – 891, (Dec. 1999).

  24. Ross, R., “Inception and propagation mechanisms of water treeing”, IEEE Transactions on Dielectrics and Electrical Insulation,  Vol. 5, No. 5,  pp. 660 – 680, (Oct. 1998).

  25. Boggs, S., Densley, J., Kuang, J., “Mechanism for impulse conversion of water trees to electrical trees in XLPE”, IEEE Transactions on Power Delivery, Vol. 13, No. 2, pp. 310 – 315 (April 1998).

  26. Dorris, D.L., Pace, M.O., Blaleck, T.V., Alexeff, I., ”,Current pulses during water treeing: Procedures and results”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 3, No. 4, pp. 523 – 528, (Aug. 1996).

  27. Amyot, N., Pelissou, S., “Field-aged cable material diagnosis by thermally stimulated currents”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 1, pp. 299 – 302,  (20-23 Oct. 1996).

  28. Junhua L., Jung T., Baolong S., “The fractal dimension estimate of water tree in XLPE dielectric”, Conference on Electrical Insulation and Electrical Manufacturing & Coil Winding Technology, pp. 177 – 179, (23-25 Sept. 2003).

  29. Shimakage, T., Wu, K., Kato, T., Okamoto, T., Suzuoki, Y., “Economic evaluation of degradation diagnosis for cables”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 412 – 415, (20-24 Oct. 2002).

  30. Jow, J., “Material differentiation by water treeing tests”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 2, pp. 500 – 503, (17-20 Oct. 1999).

  31. Suzuki, K., Tanaka, Y., Takada, T., Ohki, Y., Takeya, C., “Space charge distribution measurement in XLPE cable for detection of the water tree location”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 2,  pp. 630 – 633, (17-20 Oct. 1999).

  32. Olley, R.H., Vaughan, A.S., Bassett, D.C., Moody, S.M., Banks, V.A.A., “Electron microscopy of water trees in XLPE”, 5th International Conference on Conduction and Breakdown in Solid Dielectrics (ICSD'95), pp. 676 – 680, (10-13 July 1995).

  33. Notingher, P.V., Radu, I., Filippini, J.C., “Electric field calculations in polymers in the presence of water trees”, 5th International Conference on Conduction and Breakdown in Solid Dielectrics (ICSD'95), pp. 666 – 670, (10-13 July 1995).

  34. Acedo, M., Frutos, F., Torres, M., Filippini, J.C., “The cylindrical capacitive model for water treeing degradation in extruded HV cables”, 5th International Conference on Conduction and Breakdown in Solid Dielectrics (ICSD'95), pp. 661 – 665, (10-13 July 1995).

  35. Hvidsten, S., Wrelius, P., Christensen, J., “Evaluation of on-site dielectric response methods for nondestructive testing of water treed MV XLPE cables”, 16th International Conference and Exhibition on Electricity Distribution, Part 1: Contributions. CIRED. (IEE Conf. Publ No. 482), Vol. 1, pp. 5 pp. (18-21 June 2001).

  36. Lanca, M.C., Marat-Mendes, J.N., Dissado, L.A., “The fractal analysis of water trees: an estimate of the fractal dimension”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 8, No. 5,  pp. 838 – 844, (Oct. 2001).

  37. Crine, J.-P., Jow, J., “Influence of frequency on water tree growth in various test cells”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 8, No. 6, pp. 1082 – 1087, (Dec. 2001).

  38. Cherukupalli, S.E., Colwell, M., Valli, G., “Evaluation of jacket materials and configurations and effect of moisture absorbing materials on preventing water tree growth in power cables”, IEEE Transactions on Power Delivery, Vol. 14, No. 3, pp. 690 – 698, (July 1999).

  39. Crine, J.-P., “Electrical, chemical and mechanical processes in water treeing”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 5, No. 5, pp. 681 – 694, (Oct. 1998).

  40. Tsujimoto, T., Nakade, M., Yagi, Y., Adachi, K., Tanaka, H., “Development of on-site diagnostic method for XLPE cable by harmonics in AC loss current”, 7th International Conference on Properties and Applications of Dielectric Materials, Vol. 1,  pp. 73 - 76, (1-5 June 2003).

  41. Crine, J.-P., Jow, J., “Influence of frequency on water treeing in polyethylene”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 1, pp. 351 – 354, (15-18 Oct. 2000).

  42. Sekii, Y., Momose, N., Takatori, K., Goto, T., “A study of water tree suppression in polymeric insulating materials”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 1, pp. 347 – 350, (15-18 Oct. 2000).

  43. Zheng Xiaoquan, Tu Demin, “Response and mechanisms of water trees in XLPE cable insulation under superposition voltage”, 6th International Conference on Properties and Applications of Dielectric Materials, Vol. 1, pp. 517 – 520, (21-26 June 2000).

  44. Radu, I., Acedo, M., Notingher, P., Frutos, F., Filippini, J.C., “A study on the dependence of water tree permittivity with time”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 2, pp. 762 – 765,  (20-23 Oct. 1996).

  45. Faremo, H., Ildstad, E., “Diagnosis and restoration of water tree aged XLPE cable materials”, IEEE International Symposium on Electrical Insulation, Vol. 2, pp. 596 – 599, (16-19 June 1996).

  46. Sarma, H., “Accelerated life tests on a new water tree retardant insulation for power cables”, IEEE Transmission and Distribution Conference, pp. 402 – 410, (15-20 Sept. 1996).

  47. Muto, H., Water treeing and the diagnostic technique”, IEEE/PES Transmission and Distribution Conference and Exhibition 2002: Asia Pacific, Vol. 2, pp. 1416 – 1419, (6-10 Oct. 2002).

  48. Teissedre, G., Visata, O.I., Filippini, J.C., “On the role of ions in the formation of water trees in polyethylene cable insulation”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 942 – 945, (20-24 Oct. 2002).

  49. Thanh, V.H., Hozumi, N., Nagao, M., Goto, T., Kato, Y., “Water tree retardant characteristics of silane crosslinked polyethylene”, International Symposium on Electrical Insulating Materials (ISEIM 2001), pp. 467 – 470, (19-22 Nov. 2001).

  50. Czaszejko, T., “Statistical analysis of water tree lengths”, IEEE International Symposium on Electrical Insulation, Vol. 1, pp. 89 – 92, (7-10 June 1998).

  51. Miyashita, T., “Retrospect of water tree discovery”, International Symposium on Electrical Insulating Materials, pp. 17 – 22, (27-30 Sept. 1998).

  52. Houlgreave, J.A., Fothergill, J.C., “Estimating the true growth rate of water trees from a series of samples taken at different ageing times”, 5th International Conference on Conduction and Breakdown in Solid Dielectrics (ICSD'95), pp. 566 – 570, (10-13 July 1995).

  53. Tanimoto, G., Shinan Wang, Aida, F., Fujiwara, Y., “A study on electrical breakdown by water treeing in XLPE”, International Symposium on Electrical Insulating Materials, pp. 431 – 434, (17-20 Sept. 1995).

  54. Jochen Jung, Patsch, R., “Selective detection of water trees in cables”, 8th International Conference on Dielectric Materials, Measurements and Applications, (IEE Conf. Publ. No. 473), pp. 53 – 56, (17-21 Sept. 2000).

  55. Werelius, P., Tharning, P., Eriksson, R., Holmgren, B., Gafvert, U., “ Dielectric spectroscopy for diagnosis of water tree deterioration in XLPE cables”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 8, No. 1, pp. 27 – 42, (Feb 2001).

  56. Given, M.J., Fouracre, R.A., MacGregor, S.J., Judd, M., Banford, H.M., “Diagnostic dielectric spectroscopy methods applied to water-treed cable”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 8, No. 6,  pp. 917 – 920, (Dec. 2001).

  57. Castellani, L., Peruzzotti, F., Zaopo, A., Cinquemani, P.L., Foulger, S., Filippini, J.C., Lachevre, V., “Evaluation of materials for WTR-insulated power cables”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 7, No. 6, pp. 818 – 824,  (Dec. 2000).

  58. Suzuki, H., Mukai, S., Ohki, Y., Nakamichi, Y., Ajiki, K., “Water-tree characteristics in low-density PE under simulated inverter voltages”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 5, No. 2, pp. 256 – 260, (April 1998).

  59. Sarma, H., “Accelerated life tests on a new water tree retardant insulation for power cables”, IEEE Transactions on Power Delivery Vol. 12, No. 2, pp. 551 – 559, (April 1997).

  60. Jonuz, B., Morshuis, P.H.F., Van Breen, H.J., Pellis, J., Smit, J.J., “Detection of water trees in medium voltage XLPE cables by return voltage measurements”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 1, pp. 355 – 358, (15-18 Oct. 2000).

  61. Qureshi, M.I., Malik, N.H., Al-Arainy, A.A., “Effects of different ionic solutions on statistical length distribution of water trees in XLPE cable insulation”, 6th International Conference on Properties and Applications of Dielectric Materials, Vol. 1, pp. 513 – 516, (21-26 June 2000).

  62. Dang Zhimin, Kang Jie, Tu Demin, “Relationships between space charge accumulation and electrical or water treeing in improved PE and XLPE by ethylene-acrylic acid copolymer”, 6th International Conference on Properties and Applications of Dielectric Materials, Vol. 1, pp. 562 – 566,  (21-26 June 2000).

  63. Hvidsten, S., Faremo, H., Benjaminsen, J.T., Ildstad, E., “Non-destructive diagnostic testing of service aged MV XLPE cables”, IEEE International Symposium on Electrical Insulation, pp. 137 – 140, (2-5 April 2000).

  64. Mukai, S., Suzuki, H., Ohki, Y., Nakamichi, Y., Ajiki, K., Li, Y., “ Role of voltage zero-crossing in propagation of water trees”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 1, pp. 300 – 303, (19-22 Oct. 1997).

  65. Suzuki, H., Ohki, Y., Nakamichi, Y., Ajiki, K., “ Water tree characteristics in low-density polyethylene under power-frequency voltages with high-frequency components”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 2, pp. 742 – 745, (20-23 Oct. 1996).

  66. Uchida, K., Nakade, M., Inoue, D., Sakakibara, H., Yagi, M., “Life estimation of water tree deteriorated XLPE cables by VLF (very low frequency) voltage withstand test”, IEEE/PES Transmission and Distribution Conference and Exhibition 2002: Asia Pacific., Vol. 3, pp. 1879 – 1884, (6-10 Oct. 2002).

  67. Hvidsten, S., Faremo, H., Eriksson, R., Wei Min, “Water treeing and condition assessment of high voltage XLPE cables”, International Symposium on Electrical Insulation, pp. 112 – 115, (7-10 April 2002).

  68. Wen, Y., Foulger, S.H., Cinquemani, P.L., Peruzzotti, F., Zaopo, A., “Development and testing of medium voltage power cables with water treeing retardant materials”, IEEE International Symposium on Electrical Insulation, Vol. 2, pp. 534 – 537, 7-10 (June 1998).

  69. Czaszejko, T., “Determination of statistical distribution of water tree lengths: Monte Carlo simulation”, 6th International Conference on Conduction and Breakdown in Solid Dielectrics (ICSD '98), pp. 333 – 336, (22-25 June 1998).

  70. Hobdell, S.B., Mainwaring, S.P., Hampton, R.N., “An investigation of the factors affecting the growth of bow tie water trees in XLPE insulation systems”, 8th International Conference on Dielectric Materials, Measurements and Applications, (IEE Conf. Publ. No. 473), pp. 47 – 52,  (17-21 Sept. 2000).

  71. Boggs, S., Xu, J., “Water treeing - filled versus unfilled cable insulation”, IEEE Electrical Insulation Magazine, Vol. 17, No. 1, pp. 23 – 29, (Jan.-Feb. 2001)

  72. Crine, J.-P., “When Taguchi meets water treeing in power cables”, IEEE Electrical Insulation Magazine, Vol. 16, No. 3, pp. 13 – 18, (May-June 2000).

  73. Hvidsten, S., Ildstad, E., Sletbak, J., Faremo, H., “Understanding water treeing mechanisms in the development of diagnostic test methods”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 5, No. 5, pp. 754 – 760, (Oct. 1998).

  74. Hvidsten, S., Ildstad, E., Holmgren, B., Werelius, P., “Correlation between AC breakdown strength and low frequency dielectric loss of water tree aged XLPE cables”, IEEE Transactions on Power Delivery, Vol. 13, No. 1, pp. 40 – 45, (Jan. 1998).

  75. Wubbenhorst, M., Hornsby, J., Stachen, M., Das-Gupta, D.K., Bulinski, A., Bamji, S., “Dielectric properties and spatial distribution of polarization in polyethylene aged under ac voltage in a humid atmosphere”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 5, No. 1, pp. 9 – 15, (Feb. 1998).

  76. Dorris, D.L., Pace, M.O., Blalock, T.V., Alexeff, I., “Current pulses during water treeing: Detection system”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 3, No. 4, pp. 515 – 522, (Aug. 1996).

  77. Crine, J.-P., Parpal, J.-L., Dang, C., “Influence of fatigue on some electrical ageing mechanisms of polymers”, IEE Proceedings - Science, Measurement and Technology, Vol. 143, No. 6,  pp. 395 – 398, (Nov. 1996).

  78. Jow, J., Dissado, L.A., “A new model for water tree propagation”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 1, pp. 333 – 336, (15-18 Oct. 2000).

  79. Boggs, S., Densley, J., Kuang, J., “Surge-induced temperature rise in water-containing defects in XLPE: Mechanism for conversion of water trees to electrical trees”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 1, pp. 311 – 314, (20-23 Oct. 1996).

  80. Notingher, P.V., Ciuprina, F., Radu, I., Filippini, J.C., Gosse, B., Jipa, S., Setnescu, T., Setnescu, R., Mihalcea, T., “Studies on water treeing and chemiluminescence on irradiated polyethylene insulated cables”, IEEE International Symposium on Electrical Insulation, Vol. 1, pp. 163 – 166, (16-19 June 1996).

  81. Katakai, S., “Design of XLPE cables and soundness confirmation methods to extra high voltage XLPE cables”, IEEE/PES Transmission and Distribution Conference and Exhibition 2002: Asia Pacific., Vol. 2, pp. 1411 – 1415, (6-10 Oct. 2002).

  82. Al-Hamouz, Z., Al-Soufi, K., Ahmed, M., Al-Ohali, M.A., Garwan, M., “Water trees diagnostic of extruded underground cables: A case study in Saudi Arabia eastern province”, IEEE/PES Transmission and Distribution Conference and Exhibition 2002: Asia Pacific., Vol. 2, pp. 1088-1093, (6-10 Oct. 2002).

  83. Hvidsten, S., Benjaminsen, J.T., “Diagnostic testing of MV XLPE cables with low density of water trees”, IEEE International Symposium on Electrical Insulation, pp. 108 – 111, (7-10 April 2002).

  84. Shimakage, T., Wu, K., Kato, T., Okamoto, T., Suzuoki, Y., “Economic evaluation of cable replacement considering annual failure probability”, IEEE International Symposium on Electrical Insulation, pp. 472 – 475, (7-10 April 2002).

  85. Alijagic-Jonuz, B., Morshuis, P.H.F., van Breen, H.J., Smit, J.J., “Detection of water trees in medium voltage cables by RVM without reference measurements”, 7th International Conference on Solid Dielectrics (ICSD '01), pp. 504 – 507, (25-29 June 2001).

  86. Toyoda, T., Mukai, S., Ohki, Y., Li, Y., Maeno, T., “Conductivity and permittivity of water tree in polyethylene”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 2, pp. 577 – 580, (17-20 Oct. 1999).

  87. Hvidsten, S., “Nonlinear dielectric response of vented water treed XLPE insulation”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 2, pp. 617 – 621, (17-20 Oct. 1999).

  88. Kawai, J., Shinagawa, J., Nakamura, S., Iida, K., Sawa, G., “A consideration of distorted ac loss-current from water treeing degraded polyethylene”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 637 – 640, Vol. 2, (25-28 Oct. 1998).

  89. Yagi, Y., Tanaka, H., Kimura, H., “ Study on diagnostic method for water treed XLPE cable by loss current measurement”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 653 - 656, Vol. 2, (25-28 Oct. 1998).

  90. Jow, J., “Electrical degradation interactions-kinetic and thermodynamic aspects of chain scission for water treeing”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 669 - 672 Vol. 2, (25-28 Oct. 1998).

  91. Kakuta, M., “Study of the voltage behavior of water tree deteriorated XLPE cables by signal current detection mode for insulation diagnosis”, International Symposium on Electrical Insulating Materials, pp. 487 – 490, (27-30 Sept. 1998).

  92. Toyoda, T., Mukai, S., Ohki, Y., Li, Y., Maeno, T., “Estimation of conductivity and permittivity of water trees in PE from space charge distribution measurements”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 8, No. 1,  pp. 111 – 116, (Feb 2001).

  93. Ohki, Y., Ebinuma, Y., Katakai, S., “Space charge formation in water-treed insulation”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 5, No. 5, pp. 707 – 712, (Oct. 1998).

  94. Sekii, Y., Momose, N., Takatori, K., Kanemitsu, Y., Goto, T., “Effect of surfactant on water tree generation in XLPE”, 7th International Conference on Properties and Applications of Dielectric Materials, Vol. 3, pp. 927 – 931, (1-5 June 2003).

  95. Boggs, S., “Mechanisms for reduction of impulse strength resulting from small water trees”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 2, pp. 547 – 551, (15-18 Oct. 2000).

  96. Patsch, R., Ortolf, M., Tanaka, J., “Hydration of ions-how does it influence water treeing?”, 5th International Conference on Properties and Applications of Dielectric Materials, Vol. 1,  pp. 410 – 413, (25-30 May 1997).

  97. Abou-Dakka, M., Bulinski, A.T., Bamji, S.S., “DC polarization characteristics of XLPE and EPR insulation subjected to water treeing”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 181 – 184, (19-22 Oct. 2003).

  98. Ramachandran, S., Reed, R.A., “TR-XLPE cables for utility power distribution: 20 years of field proven, value added performance”, Rural Electric Power Conference, pp. B4-1 - B4-7, (4-6 May 2003).

  99. Chunxi Zhang, Shouguo Sheng, Jiaxiang Yang, Xiaochun Chi, “Study on DC component caused by water treeing in XLPE cable”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 926 – 929, (20-24 Oct. 2002).

  100. Frutos, F., Acedo, M., Radu, I., Jimenez, A., Perez-Gomez, J.A., Filippini, J.C., Jadraque, A., “A new approach to the modelling of the conduction processes in a water tree degraded LDPE”, 7th International Conference on Solid Dielectrics (ICSD '01), pp. 167 – 170, (25-29 June 2001).

  101. Acedo, M., Radu, I., Frutos, F., Filippini, J.C., Jimenez, A., Perez-Gomez, J.A., Jadraque, A., “The characterization of a LDPE affected by different levels of water tree degradation using absorption current measurements”, 7th International Conference on Solid Dielectrics (ICSD '01.), pp. 508 – 511, (25-29 June 2001).

  102. Sarma, H., “Accelerated aging of TRXLPE insulated cables using water-filled tanks”, IEEE Transmission and Distribution Conference, Vol. 1, pp. 40 – 45, (11-16 April 1999).

  103. Given, M.J., Judd, M., MacGregor, S.J., Mackersie, J., Fouracre, R.A., “Broad band dielectric spectroscopy as a diagnostic technique for water tree growth in cables”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 118 – 121, Vol. 1, (17-20 Oct. 1999).

  104.  Ildstad, E., Faremo, H., “Application of dielectric response measurements for condition assessment of service aged XLPE cables”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 122 – 127, Vol. 1, (17-20 Oct. 1999).

  105. Mukai, S., Ohki, Y., Li, Y., Maeno, T., “Time-resolved space charge observation in water-treed XLPE”, Conference on Electrical Insulation and Dielectric Phenomena, pp. 645 - 648 Vol. 2, (25-28 Oct. 1998).

  106. Pelissou, S., St.-Antoine, S., “Influence of cable processing on the insulation impurity content”, IEEE International Symposium on Electrical Insulation, Vol. 1, pp. 97 – 100, (7-10 June 1998).

  107.  Kuschel, M., Kryszak, B., Kalkner, W., “Investigation of the non-linear dielectric response of water tree-aged XLPE cables in the time and frequency domain”, 6th International Conference on Conduction and Breakdown in Solid Dielectrics (ICSD '98), pp. 85 – 88, (22-25 June 1998).

  108. Hvidsten, S., Ildstad, E., Faremo, H., “Mechanisms causing nonlinear dielectric response of water treed XLPE cables”, 6th International Conference on Conduction and Breakdown in Solid Dielectrics (ICSD '98), pp. 73 – 78, (22-25 June 1998).

  109. Hossam-Eldin, A.A., Al Hasawi, W., Ali, M.M., “Study and modeling of water treeing in solid insulation of power cables”, 6th International Conference on Conduction and Breakdown in Solid Dielectrics (ICSD '98), pp. 89 – 92, (22-25 June 1998).

  110. Pispiris, C.S., “Cable diagnosis. In-situ tests with returned voltage diagnosis method in Romania”, Part 1: Contributions CIRED. 16th International Conference and Exhibition on Electricity Distribution (IEE Conf. Publ No. 482), Vol. 1, (18-21 June 2001).

  111. Yutao Zhu, Ho Gyu Yoon, Suh, K.S., “Electrical properties of silane crosslinked polyethylene in comparison with DCP crosslinked polyethylene”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 6, No. 2, pp. 164 – 168, (April 1999).

  112. Nikolajevic, S.V., “The influence of the water on water absorption and density of XLPE cable insulation”, IEEE Transactions on Power Delivery, Vol. 13, No. 2, pp. 297 – 303, (April 1998).

  113. Suh, K.S., Chang Ryong Lee, Yutao Zhu, Jangseob Lim, “Electrical properties of chemically modified polyethylenes”, IEEE Transactions on Dielectrics and Electrical Insulation,  Vol. 4, No. 6, pp. 681 – 687, (Dec. 1997).

  114. Al-Arainy, A.A., Malik, N.H., Qureshi, M.I., “A hybrid system of long term accelerated water tree testing of cables at King Saud University”, 6th International Conference on Properties and Applications of Dielectric Materials, Vol. 1, pp. 550 – 553, (21-26 June 2000).

  115. Patsch, R., Jung, J., “Improvement of the return voltage method for water tree detection in XLPE cables”, IEEE International Symposium on Electrical Insulation, pp. 133 – 136, (2-5 April 2000).

  116. Abou-Dakka, M., Bamji, S., Bulinski, A., “Space charge distribution measurements in XLPE and EPR”, Conference on Electrical Insulation and Dielectric Phenomena, Vol. 1, pp. 23 – 27, (19-22 Oct. 1997).

  117. Nikolajevic, S.V., Stojanovic, B.B., “The influence of water in XLPE cable conductor on XLPE insulation breakdown voltage and partial discharge”, IEEE International Symposium on Electrical Insulation, Vol. 2, pp. 604 – 607, (16-19 June 1996).

  118. Bulinski, A.T., So, E., Bamji, S.S., “A current-comparator technique for measuring harmonic distortion of the loss current in high voltage cable insulation”, Conference on Precision Electromagnetic Measurements (Conference Digest 2002), pp. 10 – 11, (16-21 June 2002).

  119. Abou-Dakka, M., Bamji, S.S., Bulinski, A.T., ‘




    Download 154.9 Kb.
    leave a comment
    Page1/3
    Date conversion03.10.2011
    Size154.9 Kb.
    TypeДокументы, Educational materials
Add document to your blog or website

страницы:   1   2   3
Be the first user to rate this..
Your rate:
Place this button on your site:
docs.exdat.com

The database is protected by copyright ©exdat 2000-2017
При копировании материала укажите ссылку
send message
Documents

upload
Documents

Рейтинг@Mail.ru
наверх